Files
b210-k7-fpga/top/x400/cpld/pwr_supply_clk_gen.v
T
7e59e9516d fpga: x400: cpld: Add support for X410 motherboard CPLD
Co-authored-by: Humberto Jimenez <humberto.jimenez@ni.com>
Co-authored-by: Javier Valenzuela <javier.valenzuela@ni.com>


Original-commit: 7015f5ed2d495f3908773b7c7d74864d0cc3871a
2021-06-10 11:56:58 -05:00

74 lines
1.9 KiB
Verilog

//
// Copyright 2021 Ettus Research, A National Instruments Brand
//
// SPDX-License-Identifier: LGPL-3.0-or-later
//
// Module: pwr_supply_clk_gen
//
// Description:
//
// Generates a clock for one motherboard power supply.
//
// Parameters:
//
// BASE_ADDRESS : Base address for CtrlPort registers.
// NUM_ADDRESSES : Number of bytes of address space to use.
//
`default_nettype none
module pwr_supply_clk_gen#(
parameter SOURCE_CLK_FREQ = 100_000_000,
parameter TARGET_CLK_FREQ = 100_000
) (
// Base clock and reset
input wire clk,
input wire rst,
// Power supply clocks
output reg pwr_supply_clk
);
//-----------------------------------------------------------------------------
// Counter Calculation / Definition
//-----------------------------------------------------------------------------
// Counter to generate the power supply switching clock
// Assumption: the ratio between the generated clock and the source clock is
// even, therefore we can produce a 50% DC clock output.
localparam MAX_COUNT = SOURCE_CLK_FREQ / TARGET_CLK_FREQ / 2;
localparam COUNTER_W = $clog2(MAX_COUNT);
reg [COUNTER_W-1:0] counter = 0;
//-----------------------------------------------------------------------------
// Clock Generation
//-----------------------------------------------------------------------------
// This process implements a simple clock divider for the power supply
// switcher.
// SAFE COUNTER START! rst is a synchronous reset generated in the
// clk domain; therefore, inherently safe.
always @(posedge clk) begin
if (rst) begin
counter <= 0;
pwr_supply_clk <= 1'b0;
end
else begin
// Add one every cycle to the counter
counter <= counter + 1'b1;
// When the counter reaches its mid value, it is reset and the output clock
// output is toggled.
if (counter == MAX_COUNT-1) begin
counter <= 0;
pwr_supply_clk <= ~pwr_supply_clk;
end
end
end
endmodule
`default_nettype wire