# # Copyright 2022 Ettus Research, a National Instruments Brand # # SPDX-License-Identifier: LGPL-3.0-or-later # # Description: # Clock definition constraints for X440 # ############################################################################### # MMCM-Related Clocks # # Note: Vivado will create generated clocks based on the default MMCM settings # configured in the clocking wizard, but we are going to dynamically change # those clocks, and so the MMCM has to be configured for the highest frequency. ############################################################################### # PLL Reference Clock (PRC) input. This goes from the LMK straight to the MMCM # input, and is used to generate the internal PRC as well as RFDC/data clocks. # Set to maximum frequency of 64 MHz. Actual frequency depends on the LMK # configuration. set pll_ref_clk_period 15.625 create_clock -name pll_ref_clk -period $pll_ref_clk_period [get_ports PLL_REFCLK_FPGA_P]